Mon – Sat: 8:00 – 17:00
+216 71 940 730/ +216 71 940 096

LEMS

LEMS

The purpose of the test is to determine the air permeability, water tightness, and wind gust resistance of windows, French windows, and doors, regardless of the materials used (wood, aluminum, PVC, mixed, etc.).

See the technical data sheet

 

The purpose of the test is to determine the air permeability, water tightness, and wind gust resistance of aluminum curtain walls.

See the technical data sheet

The purpose of the test is to determine the damage caused by the impact of a soft, heavy object on the face of a closed door leaf, fixed in its frame as part of a door assembly.

See the technical data sheet

The test consists of determining the permanent deformation caused by a vertical load applied to an open door leaf fixed in its frame as part of a door assembly.

See the technical data sheet

The purpose of the test is to determine the forces required to open/close hinged and sliding doors, and to engage/release and lock/unlock the hardware using a key or handle.

See the technical data sheet

The purpose of the test is to determine the water tightness of installed facades on site following the application of a constant and specified quantity of water (5 l/min/m ± 10%) in a continuous film on the external face of the curtain wall installed on a building for 30 minutes, while checking for water leaks.

See the technical data sheet

The purpose of the test is to determine the behavior of fixed guardrails following the application of static and dynamic loads.

See the technical data sheet